Skip to content

Atsargumo priemonės ir teisinė informacija



⬇️ multi ⬇️

BellaBambi® Cups

Attention

This device is not intended for use by persons (including children) with limited physical, sensory, or mental capabilities or lack of sufficient experience and/or knowledge, unless they are supervised or instructed on how to use the device by a person responsible for their safety. Children must be supervised to ensure they do not play with the device. This device may be used by children aged 8 years and older and persons with limited physical, sensory, or mental capabilities or lack of experience and knowledge if they are supervised or instructed on the safe use of the device and understand the associated dangers.

Application and principle

Loading image:

Squeeze, place, and release. You can pull the suction cup over the skin or leave it in place.

If it is uncomfortable for you to use, squeeze "BellaBambi®" less strongly or use a gentler intensity. Always pay attention to how you feel!

ATTENTION:
Do not use "BellaBambi®" statically in one place for more than 20 seconds to avoid skin marks. Static use on the face is completely prohibited.

Do not use on:

Scrotum, genital organs, anus, eyes (eyelids), lips and oral cavity, lymph nodes, armpits and groin.

Use only after consulting a doctor about

Pregnancy, acute injuries, open wounds, inflammations, varicose veins, tendency to bruising, ulcers caused by diabetes and vascular diseases, irritable skin conditions such as psoriasis or urticaria, treatment with blood-thinning drugs, tumors, Sudeck's disease, and all unclear and acute diseases.

Cleaning and storage

BellaBambi® is very easy to wash in the dishwasher or by hand with mild soapy water. After drying, treat with a disinfectant suitable for silicone (without propanol, phenol derivatives, or alkylamines (glucoprotamine)). Note: if the "BellaBambi®" is very dirty, you can also boil it - like a baby pacifier. To do this, place the "BellaBambi®" in a clean pot, completely cover with water, and boil for at least five minutes.
Children should not clean the cup without supervision.
Suitable cleaning and disinfecting agents can be found at www.bellabambi.de

Recommendations

In some areas, it is useful to use oil that supports lubrication. BellaBambi® can also be combined with hyaluronic fluid, cellulite creams, or body lotions.

Guarantee

We provide a two-year manufacturer warranty for all cups. Please note that it only applies if only manufacturer-recommended combinations and cleaning agents are used.
You can find the warranty conditions here:
www.bellabambi.de/garantie


BellaBambi® multi

Thank you for your purchase
Congratulations on acquiring BellaBambi® multi. You now have a versatile and long-lasting product that you can use for care and well-being purposes. The suction cups and connecting tube are skin-friendly and made only in Germany. To ensure the new product is as successful as possible and you can enjoy it for as long as possible, please read this user manual carefully.
Sincerely thank you!
Your "BellaBambi®" team

Loading image:

Description

1. Intensity regulator
2. Hose connection
3. On / off button

Explanation of symbols

WARNING Warning about risk of injury or health hazard

ATTENTION Safety instructions regarding possible device and/or accessory damage

Link to important information

Use only indoors

Protective insulated device of protection class II

Not suitable for children under three years of age

Purpose and principle

Using "BellaBambi® multi" you can perform a soothing negative pressure massage on yourself or others. The massage can have a relaxing or stimulating effect and is often used to treat tension, adhesions, pain, and fatigue in the fields of beauty, wellness, and sports.
BellaBambi® multi is intended for external use for vacuum massage of individual parts of the human body. It is not a medical product, it cannot be used for therapeutic purposes, and it cannot replace medical treatment.

Under such circumstances do not use BellaBambi® multi:

- High-risk pregnancy
- Skin injuries, skin defects, and skin inflammations (e.g., scratches, ulcers, sunburns)
- Tendency to bleed or people with blood clotting disorders
- Blood and lymphatic diseases
- Skin cancer
- Do not use BellaBambi® on:
◦ eyes and eyelids
◦ ear canal, lips, and oral cavity
◦ nipples and genital organs
◦ anus
- Known allergies to the product's materials and additional ingredients

BellaBambi® multi should be used only after thoroughly examining the circumstances, if: pregnancy, Sudeck's disease, cancer and malignant diseases, tendency to bleeding and blood clotting disorders, use of blood-thinning medications, irritable skin conditions (e.g., psoriasis, urticaria), as well as all unclear diseases.

BellaBambi® multi should be used only after thoroughly examining the circumstances, if: pregnancy, Sudeck's disease, cancer and malignant diseases, tendency to bleeding and blood clotting disorders, use of blood-thinning medications, irritable skin conditions (e.g., psoriasis, urticaria), as well as all unclear diseases. If your skin reacts sensitively to application (e.g., bruising quickly appears, persistent redness or itching) or you feel general discomfort and pain, stop the application immediately and consult a doctor.

If "BellaBambi®" is left in place, pay attention to our empirical data on how the skin may react to moderate absorbency:

Funny smell

Pressure point : į ≈ 1-2 min
Pain : į ≈ 2-3 min
Cup mark : į ≈ 5 min

Normal room

Pressure point : į ≈ 2 min
Pain : į ≈ 4 min
Cup mark : į ≈ 7 min

Strong odor

Pressure point : į ≈ 5 min
Pain : į ≈ 7 min
Cup mark : į ≈ 9 min

* Bruises should not be confused with hematomas, so-called bruises, which occur due to traumatic impacts (blows, falls, etc.). Cup marks indicate blood leakage into the fascial tissue, which (usually) occurs without vascular damage and is never (!) painful. Moreover, these marks disappear without the yellow-green color characteristic of hematomas.

Safety instructions

Attention: to ensure your safety, carefully follow the safety instructions provided below and familiarize other device users with them. Keep these user instructions in a safe place.

- Before using the device, carefully and thoroughly read these operating instructions and follow the sequence of procedures.
- After use, the vacuum pump and accessories can be placed back into the bag. Therefore, there is no packaging material to dispose of.
- The device can only be connected to an alternating current power supply with a voltage matching the rated voltage indicated on the plate on the pump housing.
- Do not pull the power cord over sharp edges and do not pinch it, do not let it hang down, and protect it from heat and oil.
- Make sure there is an electrical outlet near the installation location.
- Arrange the power cable and connecting hose so that no one can trip over them.
- Do not place the device on the floor in the bathroom.
- Do not use the device near water in bathtubs, sinks, or other containers.
- Never immerse the device in water. Never allow liquids to enter the device.
- Do not cover the device with clothes, bath towels, or similar items (risk of overheating!).
- Do not place the device on hot surfaces, such as stoves, and do not use it near open flames.
- Turn off the device after each use. Do not pull the power plug from the socket by the cord or with wet hands.
- Do not use the device unattended.
- Always unplug the device before cleaning and maintenance.
- Before each use, check that the device is not damaged. Do not use the device if
◦ the pump housing or power cords are damaged.
◦ the device has been dropped.
- If any of the above cases occur, send the device to our service department for inspection or professional repair (see page). Never attempt to repair the device yourself.
- This device may be used by children aged eight (8) years and older and persons with reduced physical, sensory, or mental capabilities or lack of experience and/or knowledge if they have been supervised or instructed concerning safe use of the device and understand the hazards involved. Children are not allowed to play with the device. Cleaning and user maintenance must not be performed by children without supervision.
- Strictly adhere to the doses and maximum usage time specified in these operating instructions!
- Do not use any accessories not recommended by the manufacturer.

Order

1. Before each use, the devices must be cleaned. See cleaning on page 6
2. Select the "BellaBambi®" applicator suitable for the body part and connect it to the vacuum pump with the connecting hose.
BellaBambi® mini is especially suitable for narrow body areas, face, hands, and feet.
BellaBambi® original can be used for the whole body, for example, back, calves, or neck.
BellaBambi® maxi is used for large areas, such as back, abdomen, or thighs.
3. Plug in the power cord and turn on the vacuum pump.
4. Set the maximum suction strength and place the "BellaBambi®" applicator. As soon as it is suctioned, reduce the suction power if necessary until it is noticeable but not unpleasant.
5. Use as intended and follow the safety instructions provided in this user manual.
6. Clean after use. See cleaning on page 6
7. Turn off and unplug from the power outlet.

For your safety, a timer is installed that automatically turns off the vacuum pump after 15 minutes. You can turn the device on again at any time using the on/off button.

Application

In general, always apply only to the skin or muscles and never directly on the spine or bony prominences. Do not massage glands and lymph nodes.

Always adjust the suction strength according to your comfort level.

Cleaning

Loading image:

Clean the vacuum cleaner only with a slightly damp, but never wet cloth. If necessary, add a few drops of detergent.

Loading image:

1. Wash the "BellaBambi®" applicator with warm soapy water or a commercial detergent by hand or in the dishwasher.
2. Thoroughly dry the BellaBambi® applicator or allow it to air dry.
3. Spray with a silicone-compatible disinfectant, i.e., free of phenol compounds or alkylamines (glucoprotamine).
4. Allow the disinfectant to act according to the manufacturer's instructions.
5. Rinse off the disinfectant residues thoroughly with clean water.
6. Dry the BellaBambi® applicator thoroughly again or allow it to air dry.

What to do when problems arise?

The program does not freeze

The device is not connected to the power supply or is turned off. → Connect the power cable and turn on the device.

The programs are not properly connected. → Check the connections of the vacuum pump and the application.

The treated skin area is very hairy. → Apply massage oil or cream, if necessary, shave.

"BellaBambi®" cuffs cannot fully adhere to the body part. → Choose a smaller "BellaBambi®" or slightly compress the "BellaBambi®" to reduce the contact area.

The timer has expired → Press the power button.

-

The application is unpleasant.

Detected inappropriate suction strength. → Reduce the suction strength so that it is noticeable but not unpleasant.

No skin care products are used. → If possible, use a topical skin care product.

Used too little or inappropriate skin care product. → Use more topical skin care product.

Technical data and environmental conditions

Permissible environmental conditions indicate the limits within which "BellaBambi® multi" can be used without risk of damage.
Permissible environmental conditions:
- From +10°C to +40°C (during operation)
- From -18°C to +60°C (storage)
- 30–75 % relative humidity


Power consumption: 230 V, 50 mA, 50/60 Hz

-

Intensity min. (controller turned all the way to the left) = -50 mbar ( Negative pressure at the device output )

Maximum intensity (controller turned all the way to the right) = -280 mbar ( Negative pressure at the device output )

Technical maintenance and repair

Vacuum pump repairs can only be performed by the manufacturer. Under no circumstances should the device be opened. Do not perform any unauthorized manipulations with the device. Otherwise, the warranty will be voided. For necessary repair or maintenance work, contact this address:


Bamberg Precision Parts Made of Elastomers eK
Industriestraße 25
D-89423 Gundelfingen
Phone: + 49 (9073) 1234
Fax: + 49 (9073) 1334
info@bellabambi.de
www.bellabambi.de

Waste disposal

Your device contains many raw materials that can be recycled. Therefore, take the device to a collection point in your city or municipality. Do not throw old devices into residual waste! In the local recycling center, inquire about the possibilities of recycling the device. If there is no disposal option in the municipality, you can return the device free of charge to "Bamberger" for professional disposal.

Back to top