Attention

This device is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities or lack of experience and/or knowledge, unless they have been supervised or instructed regarding the use of the device by a person responsible for their safety. Children must be supervised to ensure that they do not play with the device. This device may be used by children aged 8 years and above and by persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge, if they have been supervised or instructed regarding the safe use of the device and have understood the dangers involved.

Application and principle

Loading image:

Squeeze together, place, and release. You can pull the suction cup over the skin or leave it in place.

If the application feels uncomfortable, squeeze BellaBambi® less firmly or use a gentler intensity. Always pay attention to your own well-being!

WARNING:
Do not use BellaBambi® statically in one spot for more than 20 seconds to avoid skin marking. Static application on the face is completely excluded.

Do not use on:

The nipples, genital organs, anus, eyes (eyelids), lips, and oral cavity, on the lymph nodes, in the armpit and in the inguinal area.

Use only after consulting a doctor for

Pregnancy, acute wounds, open wounds, inflammations, varicose veins, tendency to bruising, ulcers caused by diabetes and vascular diseases, irritating skin diseases such as psoriasis or urticaria, therapies with anticoagulant drugs, tumors, Sudeck's disease, and all unclear and acute diseases.

Cleaning and storage

BellaBambi® is very easy to clean in the dishwasher or manually with mild soapy water. After drying, treat with a suitable disinfectant for silicone (without propanol, phenol derivatives, or alkylamines (glucoprotamine)). Please note: If BellaBambi® is very dirty, you can also boil it – just like a baby doll. To do this, place BellaBambi® in a clean pot, cover it completely with water, and boil for at least five minutes.
Children should not clean the cup without supervision.
You can find suitable cleaning agents and disinfectants at www.bellabambi.de

Recommendations

For some applications, an oil is useful to support lubrication. BellaBambi® can also be combined with hyaluronic acid, anti-cellulite creams, or body lotions.

Guarantee

We offer a two-year manufacturer warranty for all cups. Please note that this only applies if only the combination and cleaning products recommended by the manufacturer are used.
You can find the warranty conditions here:
www.bellabambi.de/garantie


BellaBambi® multi

Thank you for your purchase
Congratulations on purchasing BellaBambi® multi. You now have a universally applicable and long-lasting product at hand when it comes to care and well-being. The suction cups and connecting tube are skin-friendly and are exclusively manufactured in Germany. To maximize the success and enjoyment of your new product for as long as possible, please read these instructions for use carefully.
Thank you very much!
Your BellaBambi® team

Loading image:

Description

1. Intensity regulator
2. Hose connection
3. On/off button

Explanation of the symbols

WARNING Warning about the risk of injury or danger to your health

WARNING Safety instructions for possible damage to the device/accessories

Reference to important information

Use only in enclosed rooms

Protective insulated device from protection class II

Not suitable for children under three years of age

Purpose and principle

With BellaBambi® multi you can offer yourself or others a soothing negative pressure massage. The massages can have a relaxing or stimulating effect and are often used to treat tension, adhesions, pain, and fatigue in the fields of beauty, wellness, and sports.
BellaBambi® multi is intended for external use in the form of a vacuum massage of individual parts of the human body. It is not a medical product, should not be used for therapeutic purposes, and cannot replace medical treatment.

Do not use BellaBambi® multi in these circumstances:

- High-risk pregnancy
- Skin injuries, skin defects, and skin inflammations (e.g., abrasions, ulcers, sunburns)
- Bleeding tendencies or people with blood clotting disorders
- Diseases of blood and lymphatic vessels
- Skin cancer
- Do not use BellaBambi® on:
◦ eyes and eyelids
◦ ear canal, lips, and oral cavity
◦ Nipples and genital organs
◦ Anus
- Known allergies to the product material and accessory components

Use BellaBambi® multi only after a complete examination of the circumstances in case of: pregnancy, Sudeck's disease, cancer and tumor diseases, tendency to bleed and blood coagulation disorders, administration of anticoagulant medications, irritable skin diseases (e.g., psoriasis, urticaria), as well as all unclear diseases.

Use BellaBambi® multi only after a complete examination of the circumstances in case of: pregnancy, Sudeck's disease, cancer and tumor diseases, tendency to bleed and blood coagulation disorders, administration of anticoagulant medications, irritable skin diseases (e.g., psoriasis, urticaria), as well as all unclear diseases. If your skin reacts sensitively to application (for example, rapid bruising, persistent redness, or itching) or if you experience general discomfort and pain, please stop immediately and consult a doctor.

If BellaBambi® is left in its place, please take into account our empirical values regarding how the skin may react to average absorption:

Sensitive skin

Pressure point : for ≈ 1-2 min
Redness : for ≈ 2-3 min
Cup brand : for ≈ 5 min

Normal skin

Pressure point : for ≈ 2 min
Redness : for ≈ 4 min
Cup brand : for ≈ 7 min

Resistant skin

Pressure point : for ≈ 5 min
Redness : for ≈ 7 min
Cup brand : for ≈ 9 min

* The marks from suction cups should not be confused with hematomas, the so-called "bruises," which are caused by traumatic effects (blows, falls, etc.). The cup marks indicate a leakage of blood in the fascial tissue, which (usually) occurs without vascular injuries and is never (!) painful. Additionally, these marks disappear without the typical yellow-green discoloration of hematomas.

Safety instructions

Attention: For your own safety, please carefully follow the following safety instructions and inform other users of the device. Keep these operating instructions in a safe place.

- Read these operating instructions carefully and completely before using the device and follow the sequence of procedures.
- The vacuum pump and applications can be put back in the bag after use. Therefore, there is no packaging material to be disposed of.
- The device may only be connected to alternating current with a voltage according to the rating plate on the pump housing.
- Do not pull the power cable over sharp edges or pinch it, do not let it hang down, and protect it from heat and oil.
- Make sure there is a power outlet near the installation site.
- Place the power cable and connecting hose so that no one can trip over them.
- The device must not be placed on the floor in the bathroom.
- Do not use the device near water contained in bathtubs, sinks, or other containers.
- Never immerse the device in water. Never allow liquids to enter the device.
- Do not cover the device with clothes, bath towels, or similar items (risk of overheating!).
- Do not place the device on hot surfaces such as stoves or similar and do not use it near open flames.
- Turn off the device after each use. The power plug must not be pulled out of the socket by the cable or with wet hands.
- Do not use the device unattended.
- Always disconnect the power plug from the socket before cleaning and maintaining the device.
- Check if the device is damaged before each use. Do not use the device if
◦ the pump housing or power cables are damaged.
◦ the device has been dropped.
- If any of the above cases occur, please send the device to our service department for inspection or professional repair (see page). Never attempt to repair the device yourself.
- This device can be used by children aged eight (8) years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and/or knowledge if they have been supervised or instructed regarding the safe use of the device and understand the hazards involved. Children must not play with the device. User cleaning and maintenance must not be carried out by children without supervision.
- Please strictly observe the doses and maximum terms specified in these operating instructions!
- Do not use additional parts that are not recommended by the manufacturer.

Commissioning

1. The applications must be cleaned before each use. See cleaning on page 6.
2. Select the appropriate BellaBambi® application for the body part and connect it to the vacuum pump using the connecting hose.
BellaBambi® mini is especially suitable for narrow areas of the body, face, hands, and feet.
BellaBambi® original can be used on the entire body, for example on the back, calves, or neck.
BellaBambi® maxi is used for applications on large areas, for example on the back, abdomen, or thighs.
3. Connect the power cable and turn on the vacuum pump.
4. Set the maximum suction power and place the BellaBambi® application. As soon as it has suctioned, reduce the suction power if necessary until it is visible but not uncomfortable.
5. Use in accordance with the intended purpose and the safety instructions in these operating instructions.
6. Clean after use. See Cleaning on page 6.
7. Turn off and unplug.

For your safety, we have installed a timer that automatically stops the vacuum pump after 15 minutes. You can restart the device at any time using the on/off button.

Application

In general, it is applied only on the skin or muscles and never directly on the spine or on bony prominences. Glands and lymph nodes should not be massaged.

Always adjust the suction power to your comfort level.

Cleaning

Loading image:

Please clean the vacuum pump only with a slightly damp cloth, never dripping. If necessary, add a few drops of detergent.

Loading image:

1. Wash/rinse the BellaBambi® application with lukewarm soapy water or commercially available liquid detergent, either by hand or in the dishwasher.
2. Dry the BellaBambi® application thoroughly or let it air dry.
3. Spray with a disinfectant suitable for silicone, that is free of phenol derivatives or alkylamines (glucoprotamine).
4. Allow the disinfectant to take effect according to the manufacturer's instructions.
5. Rinse off disinfectant residues thoroughly with clean water.
6. Dry the BellaBambi® application thoroughly again or let it air dry.

What should you do in case of problems?

The application does not crash

The device is not connected to the network or is turned off. → Connect the cable to the network and turn on the device.

The applications are not connected correctly. → Check the connections to the vacuum pump and the application.

The skin area to be treated is very hairy. → Apply oil or massage cream, shave if necessary.

The BellaBambi® opening cannot fully support the body side. → Choose a smaller BellaBambi®, or gently squeeze the BellaBambi® to reduce the contact area.

Timer expired → Press the on/off button.

-

The application is unpleasant.

An incorrect suction power is set. → Reduce the suction power so that it is visible but not uncomfortable.

No skin care product is used. → Use a lubricating skin care product, if possible.

Too little/incorrect skincare product is used. → Use a more moisturizing skincare product.

Technical data and environmental conditions

"Permissible ambient conditions indicate the limits within which BellaBambi® multi can be used without risk of damage.
Permissible environmental conditions:

  • +10°C to +40°C (operating)
  • -18°C to +60°C (storage)
  • 30% to 75% relative humidity

Power consumption: 230 VAC, 50 mA, 50/60 Hz"

-

Min. intensity (control fully oriented to the left) = -50 mbar ( Negative pressure at the device outlet )

Maximum intensity (control fully oriented to the right) = -280 mbar ( Negative pressure at the device outlet )

Maintenance and repairs

Repairs to the vacuum pump can only be carried out by the manufacturer. The device must not be opened under any circumstances. Do not perform unauthorized manipulations on the device. Otherwise, you will void the warranty. For any necessary repair or maintenance work, please contact the following address:


Bamberg Precision Parts Made of Elastomers eK
Industriestraße 25
D-89423 Gundelfingen
Phone: + 49 (9073) 1234
Fax: + 49 (9073) 1334
info@bellabambi.de
www.bellabambi.de

Waste removal

Your device contains numerous raw materials that can be recycled. Therefore, please return the device to a collection point in your city or municipality. Please do not dispose of old devices in residual waste! Please inquire at your local recycling center about the options for recycling your device. If municipal disposal is not possible, you can return the device free of charge to Bamberger for professional disposal.

Back to top