Skip to content

Önlemler ve yasal bilgiler



⬇️ multi ⬇️

BellaBambi® Cups

Attention

This device is not designed to be used by persons (including children) with limited physical, sensory, or mental capabilities or lack of experience and/or knowledge unless they are supervised by a person responsible for their safety or instructed on the use of the device. Children should be supervised to ensure that they do not play with the device. This device can be used by children aged 8 and above and persons with limited physical, sensory, or mental capabilities or lack of experience and knowledge if they are supervised or instructed on the safe use of the device and understand the associated hazards.

Application and principle

Loading image:

Squeeze, attach, and release together. You can pull the suction cup off your skin or leave it in place.

If you find the application uncomfortable, squeeze BellaBambi® less or use a softer intensity. Always take care of your own well-being!

WARNING:
To prevent marks on the skin, do not use BellaBambi® statically in one place for more than 20 seconds. Static application on the face is completely excluded.

Do not use on:

Membrane tips, sexual organs, anus, eyes (eyelids), lips and oral cavity, on lymph nodes, under the armpit and in the groin area.

Use only after consulting a doctor for the following conditions

Pregnancy, acute injuries, open wounds, inflammations, varicose veins, tendency to bruise, ulcers caused by diabetes and vascular diseases, irritant skin diseases such as psoriasis or hives, treatments with blood-thinning drugs, tumors, Sudeck's disease, and all uncertain and acute diseases.

Cleaning and storage

BellaBambi® is very easy to clean in the dishwasher or by hand with mild soapy water. After drying, treat it with a disinfectant suitable for silicone (free of propanol, phenol derivatives, or alkylamines (glucoprotamin)). Please note: If BellaBambi® is very dirty, you can boil it just like a baby doll. To do this, place BellaBambi® in a clean pot, cover it completely with water, and boil for at least five minutes.
Children should not clean the cup without supervision.
You can find suitable cleaning agents and disinfectants at www.bellabambi.de

Recommendations

In some applications, an oil is useful to support slipperiness. BellaBambi® can also be combined with hyaluronic fluid, cellulite creams, or body lotions.

Guarantee

We provide a two-year manufacturer warranty for all cups. Please note that this is only valid when using combinations and cleaning products recommended by the manufacturer.
You can find the warranty conditions here:
www.bellabambi.de/garantie


BellaBambi® multi

Thank you for your purchase
Congratulations on purchasing BellaBambi® multi. Now you have a universally applicable and durable product at hand when it comes to care and well-being. The suction cups and connecting pipe are skin-friendly and are only produced in Germany. To maximize the success and enjoyment of your new product for as long as possible, please read these instructions for use carefully.
Thank you very much!
Your BellaBambi® team

Loading image:

Description

1. Density regulator
2. Hose connection
3. On/off button

Explanation of the symbols

WARNING Risk of injury or danger to your health warning

WARNING Safety instructions for possible damages to the device/accessories

Reference to important information

Use only in closed rooms

Protective insulated device with protection class II

Not suitable for children under three years old

Purpose and principle

With BellaBambi® multi, you can perform a relaxing negative pressure massage on yourself or others. Massages can have a relaxing or stimulating effect and are generally used in the fields of beauty, health, and sports to treat tension, adhesions, pain, and fatigue.
BellaBambi® multi is designed for external use as vacuum massage on individual parts of the human body. It is not a medical product, should not be used for treatment purposes, and cannot replace medical treatment.

Do not use BellaBambi® multi under these conditions:

- Pregnancies at risk
- Skin injuries, skin defects, and skin inflammations (e.g., abrasions, ulcers, sunburn)
- People with bleeding tendency or blood clotting disorders
- Diseases of blood and lymph vessels
- Skin cancer
- Do not use BellaBambi® products on:
◦ Eyes and eyelids
◦ Ear canal, lips, and oral cavity
◦ Nipples and genital organs
◦ Anus
- Known allergies to product material and accessory components

Use BellaBambi® multi only after a comprehensive examination in the following cases: pregnancy, Sudeck's disease, cancer and tumor diseases, bleeding tendency and blood clotting disorders, use of blood-thinning medication, irritant skin diseases (e.g., psoriasis, urticaria), and all uncertain diseases.

Use BellaBambi® multi only after a comprehensive examination in the following cases: pregnancy, Sudeck's disease, cancer and tumor diseases, bleeding tendency and blood clotting disorders, use of blood-thinning medication, irritant skin diseases (e.g., psoriasis, urticaria), and all uncertain diseases. If your skin reacts sensitively to the application (e.g., rapid bruising, persistent redness, or itching) or if you feel general discomfort and pain, please stop immediately and consult a doctor.

If BellaBambi® is left in place, please pay attention to our empirical values regarding how the skin may react to medium absorbency:

Sensitive skin

Pressure point : for ≈ 1-2 min
Redness : for ≈ 2-3 min
Cup sign : for ≈ 5 min

Normal skin

Pressure point : for ≈ 2 min
Redness : for ≈ 4 min
Cup sign : for ≈ 7 min

Healthy skin

Pressure point : for ≈ 5 min
Redness : for ≈ 7 min
Cup sign : for ≈ 9 min

* Cupping marks should not be confused with hematomas called "bruises" caused by traumatic effects (blows, falls, etc.). Cupping marks indicate a blood leakage that occurs in the fascia tissue (usually) without vascular damage and is never (!) painful. Additionally, these marks disappear without the yellow-green discoloration characteristic of hematomas.

Safety instructions

Attention: For your own safety, please carefully follow the safety instructions below and inform other users of the device about them. Keep these instructions in a safe place.

- Read these instructions carefully and completely before using the device and follow the procedure.
- The vacuum pump and applications can be returned to the bag after use. Therefore, there is no packaging material to be discarded.
- The device can only be connected to alternating current with the voltage specified on the nominal value plate on the pump body.
- Do not pull or pinch the power cord on sharp edges, do not let it hang down, and protect it from heat and oil.
- Make sure there is an electrical outlet near the installation site.
- Arrange the power cord and connection hose so that no one can trip over them.
- The device should not be placed on the floor in the bathroom.
- Do not use the device near water in bathtubs, sinks, or other containers.
- Never immerse the device in water. Never allow liquid to enter the device.
- Do not cover the device with clothing, bath towels, or similar items (risk of overheating!).
- Do not place the device on stoves or similar hot surfaces and do not operate it near open flames.
- Turn off the device after each use. The electrical plug should not be pulled from the cable or from the socket with wet hands.
- Do not operate the device unattended.
- Always unplug the device before cleaning and maintenance.
- Check the device for damage before each use. Do not operate the device in the following cases:
◦ if the pump body or power supply cables are damaged.
◦ if the device has been dropped.
- If any of the above situations occur, please send the device to our Service department for inspection or professional repair (see page). Never attempt to repair the device yourself.
- This device can be used by children aged eight (8) and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and/or knowledge if they have been given supervision or instruction concerning the safe use of the device and understand the hazards involved. Children should not play with the device. Cleaning and user maintenance should not be performed by children without supervision.
- Please strictly adhere to the dosages and maximum time limits specified in these instructions!
- Do not use any additional parts not recommended by the manufacturer.

Commissioning

1. Applications must be cleaned before each use. See the cleaning section on page 6.
2. Select the BellaBambi® application suitable for the body area and connect it to the vacuum pump using the connection hose.
BellaBambi® mini is especially suitable for narrow areas of the body, face, hands, and feet.
BellaBambi® original can be used on the whole body, for example back, calves, or neck.
BellaBambi® maxi is used for large area applications such as back, abdomen, or thighs.
3. Plug in the power cord and turn on the vacuum pump.
4. Adjust the maximum suction power and attach the BellaBambi® application. As soon as it is suctioned, reduce the suction power if necessary until it is noticeable but not uncomfortable.
5. Use according to the intended purpose and the safety instructions in this user manual.
6. Clean after use. See cleaning on page 6.
7. Turn off and unplug.

For your safety, we have set a timer that automatically turns off the vacuum pump after 15 minutes. You can restart the device at any time using the on/off button.

Application

In general, apply only to the skin or muscles and never directly to the spine or bone protrusions. Glands and lymph nodes should not be massaged.

Always adjust your strength according to your comfort level.

Cleaning

Loading image:

Please clean the vacuum pump only with a slightly damp, never dripping wet cloth. Add a few drops of detergent if necessary.

Loading image:

1. Wash/rinse the BellaBambi® applicator by hand or in the dishwasher with warm soapy water or a commercially available dish detergent.
2. Dry the BellaBambi® applicator thoroughly or let it air dry.
3. Spray a disinfectant suitable for silicone, that is, one that does not contain phenol derivatives or alkylamines (glucoprotamine).
4. Wait for the disinfectant to take effect according to the manufacturer's instructions.
5. Rinse the disinfectant residues thoroughly with clean water.
6. Dry the BellaBambi® applicator thoroughly again or let it air dry.

What to do in case of a problem?

The application does not freeze

The device is not connected to the network or is turned off. → Plug in the network cable and turn on the device.

Applications are not connected correctly. → Check the vacuum pump and the connections on the application.

The skin area to be treated is very hairy. → Apply massage oil or cream, shave if necessary.

The openness of BellaBambi® cannot rely entirely on the body part. → Choose a smaller BellaBambi® or gently squeeze BellaBambi® to reduce the contact area.

The timer has expired → Press the power button.

-

The application is not nice.

Incorrect suction power set. → Reduce the suction power to a level that is noticeable but not uncomfortable.

No skincare product has been used. → If possible, use a lubricating skincare product.

Very few/wrong skincare products are used. → Use a more lubricating skincare product.

Technical data and environmental conditions

The permitted environmental conditions indicate the limits within which BellaBambi® multi can be used without risk of damage.
Permitted environmental conditions:

  • +10°C to +40°C (during operation)
  • -18°C to +60°C (storage)
  • 30% to 75% relative humidity


Power consumption: 230 Vac, 50 mA, 50/60 Hz

-

Density min. (turned left until the end of the control) = -50 mbar ( Negative pressure at the device outlet )

Density max. (turn right until the end of the control) = -280 mbar ( Negative pressure at the device outlet )

Maintenance and repair

Repair of the vacuum pump can only be performed by the manufacturer. The device must not be opened under any circumstances. Do not perform any unauthorized operations on the device. Otherwise, you will void your warranty. For necessary repair or maintenance work, please contact the following address:


Bamberg Precision Parts Made of Elastomers eK
Industriestraße 25
D-89423 Gundelfingen
Phone: + 49 (9073) 1234
Fax: + 49 (9073) 1334
info@bellabambi.de
www.bellabambi.de

Waste disposal

Your device contains many recyclable raw materials. Therefore, please return the device to a collection point in your city or municipality. Please do not throw old devices into the trash! Please get information from your local recycling center about options for recycling your device. If disposal by the municipality is not possible, you can return the device to Bamberger free of charge for professional disposal.

Back to top